Last Modified: 11-29-2007 |
1.6 J |
|
Service Category: Engine/Hybrid System |
Section: Engine Control |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000002225015X |
|
Title: 3UR-FE ENGINE CONTROL: SFI SYSTEM: DESCRIPTION (2008 Sequoia) |
DESCRIPTION
This circuit opens and closes the Intake Air Control Valve (IACV) in response to the engine load in order to increase the intake efficiency (ACIS: Acoustic Control Induction System).
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
|
1.
|
PERFORM ACTIVE TEST USING TECHSTREAM (OPERATE VSV FOR ACIS)
|
(a) Disconnect the vacuum hose from port F on the vacuum switching valve (for ACIS).
(b) Connect the Techstream to the DLC3.
(c) Start the engine.
(d) Enter the following menus: Powertrain / Engine and ECT / Active Test / Active the VSV for Intake Control.
(e) Operate the VSV for ACIS.
(f) Check the VSV air flow when switching the VSV.
OK:
|
Test Condition
|
Specified Condition
|
|
VSV is ON
|
Air from port E flows out through port F
|
|
VSV is OFF
|
Air from port E flows out through air filter
|
| OK |
|
|
|
2.
|
CHECK VACUUM HOSES (VACUUM SWITCHING VALVE - INTAKE AIR CONTROL VALVE, INTAKE MANIFOLD)
|
| OK |
|
|
|
3.
|
INSPECT INTAKE MANIFOLD (INTAKE AIR CONTROL VALVE)
|
(a) Inspect the intake air control valve
.
| OK |
|
|
|
5.
|
INSPECT VACUUM SWITCHING VALVE
|
(a) Inspect the vacuum switching valve
.
| OK |
|
|
|
6.
|
CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE - ECM AND INTEGRATION RELAY)
|
(a) Remove the EFI No. 2 fuse from the engine room relay block.
(b) Check the EFI No. 2 fuse.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
EFI NO. 2 fuse
|
Always
|
Below 1 Ω
|
(d) Reinstall the EFI No. 2 fuse.
(e) Disconnect the intake air control valve connector.
(f) Disconnect the ECM connector.
(g) Remove the integration relay from the engine room relay block.
(h) Disconnect the 1B integration relay connector.
(i) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
D40-2 - D56-62 (ACIS)
|
Always
|
Below 1 Ω
|
|
D40-1 - 1B-4
|
Always
|
Below 1 Ω
|
|
D40-2 or D56-62 (ACIS) - Body ground
|
Always
|
10 kΩ or higher
|
|
D40-1 or 1B-4 - Body ground
|
Always
|
10 kΩ or higher
|
| OK |
|
|
|